OVERVIEW
The CP93 is an electronic controller designed to operate access automation
systems (e.g. swing gates, sliding gates, roller shutter door operators etc.)
that incorporate either a single or double single phase, reversible AC induction
motor. The controller has various pre-configured inputs and outputs in order
to operate these types of systems in addition to many programmable features.
The user interface is enhanced using a three character digital display. Combined with two pushbuttons to navigate through the programming menu and a further pushbutton to select the required function, the programming of the controller to suit a multitude of requirements is very quick and easy. The board is fitted with diagnostic LED's for easier fault finding and installation.
The controller uses either limit switch inputs or a timer system to suit the end of travel limits for the particular installation.
In order to prolong the life of the motor switching relays, the controller incorporates zero crossing switching. This includes the ability to adjust the cross over point until minimum arcing of the relay contacts occur.
It is the all in one solution for new AC gate motors systems.
It is also the ideal replacement for an existing system where there is either no longer support or service available for the controller, or the controller has been damaged beyond repair by lightning or electrical surges.
FEATURES
GENERAL FEATURES
Incorporates protection against lightning and high voltage surges. Three digit,
seven segment LED display with three buttons for programming features. Status
of each feature programmed can be easily determined via display. On board
TEST button to activate standard trigger input. Easily removable connectors.
OPTIONAL INPUTS
| Standard trigger input with the following selectable parameters: | ||
| — Repeated triggers start, stop and reverse motor(s). | STANDARD | |
| — Repeated triggers start and reverse motor(s) | REVERSING | |
| — Operate in open direction only with automatic closing after preset auto close time. Auto close time is programmable. | CONDOMINIUM | |
| — Auto reverse on clearing standard closing protection input. | PIRAC MODE | |
| Trigger input to operate motor(s) in opening direction only.
Using combination of standard and free exit inputs: |
FREE EXIT | |
| — Separate operation of motor(s) in each direction with emergency stop as separate input to stop motor(s) | PLC MODE | |
| — Constant activation of input to operate motors with separate operation in either direction. | DEADMAN CONTROL | |
| Partial cycle opening of master motor for programmed time
with automatic closing. Automatic close time adjustable. |
PEDESTRIAN OPENING | |
| Independent limit input for both motors in both directions
configurable for NO* or NC* contacts |
LIMIT SWITCH INPUT | |
| SAFETY INPUTS | ||
| Safety device input programmed to stop and reverse motor(s) when closing in one direction. Input configurable for NO* or NC* contacts | STANDARD CLOSING BEAM OR INDUCTIVE LOOP INPUT | |
| Safety device input programmed to stop and reverse motor(s) when opening. Input configurable for NO* or NC* contacts. | OPENING BEAM OR INDUCTIVE LOOP INPUT | |
| Emergency stop input that will cut power to motors during operating cycle regardless of operating mode. | E-STOP | |
| ANCILLARY FUNCTION INPUTS | ||
| Independent control of pillar light relay. | PILLAR LIGHT CONTROL | |
| — Activate for preset timer period. — Activate to switch ON or OFF. |
||
| ANCILLARY OUTPUTS 12V DC output to power ancillary components. (e.g. Radio receivers, infra red beams etc.) |
ANCILLARY 12V DC | |
| 12V DC output to power ancillary components. (e.g. Radio receivers, infra red beams etc.) | ||
| Status indicator provides remote and local indication of gate status | STATUS LED | |
| Gate operating direction (opening/closing) Gate end of travel position (open/closed) |
||
| Potential free contact closes for a programmed period. | PILLAR LIGHT TIMER | |
| Potential free contact closes for programmed period on start up of MASTER motor in opening direction only. NO* or NC* contacts selectable. | SOLENOID/ MAGNETIC LOCK RELAY |
|
DIMENSIONS
Mounting hole set A - 112.5mm X 103.5mm between Ø4.5mm hole centres.
Mounting hole set B - 156.5mm X 135mm between Ø4mm hole centres.
Maximum height - 43mm.
SPECIFICATIONS
INPUTS
OUTPUTS
TIMERS
ENVIRONMENTAL